TM 9-2320-364-34-2
6-30
6-3. ALTERNATOR ASSEMBLY REPAIR (200 AMP) (CONT).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(14)
Coat threads of screws (36) with sealing compound.
(15)
Position matchmarks of heat sink (34) and front housing (35) then secure with nine lockwashers (37) and
screws (36). Tighten screws to 20 lb-in (2.2 Nm).
NOTE
Ensure installed wires do not interfere with free spinning of shaft.
(16)
Coat threads of screws (30) with sealing compound.
(17)
Position phase leads (33) on heat sink (34) with six washers (32), lockwashers (31) and screws (30).
Tighten screws to 20 lb-in (2.2 Nm).
35
34
30
37
36
32
34
33
31
MATCHMARKS
|