TM 9-2320-364-34-2
6-31
(18)
Install brown wire (27) and red wire (28)
on terminal strip (29) with two screws (26).
(19)
Install large gauge B+ lead (23), washer
(22), lockwasher (21) and bolt (20) on 24
volt connection (24) inside control unit
(25).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(20)
Coat connections of wires on terminal strip
(29) with adhesive sealant.
(21)
Coat edge of cover (18) with adhesive
sealant and four screws (16) with sealing
compound.
(22)
Install cover (18) on front housing (19)
with four lockwashers (17) and screws
(16). Tighten screws to 10 lb-in (1.1 Nm).
(23)
Install pulley bushing (15) on shaft (11).
(24)
Install fan (14) on shaft (11) with washer
(13) and locknut (12). Tighten locknut to
50 lb-ft (58 Nm).
19
18
17
23
22
25
16
20
24
21
26
27
26
28
29
12
13
15
11
14
|