TM 9-2320-364-34-3
16-87
To avoid damage to load cell
cable and tension load cell,
do not allow cell to turn when
installing nut.
Ensure that nuts have at
least two full threads
showing after installing on
load cell.
(6)
Position hoist assembly (1) into hoist mount
(7) and install front nut (6) on tension load
cell (5).
(7)
Install end cap (4), swivel nut (3) and jam
nut (2) on tension load cell (5). Install jam
nut loosely.
(8)
Adjust overload switch to 0.12 in. (3 mm)
by loosening or tightening nut (6) until gap
between hoist assembly (1) and hoist
mount (7) is obtained.
(9)
Tighten jam nut (2) on tension load cell (5).
(10)
Remove lifting device from hoist
assembly (1).
|