16-24. MANUAL OVERRIDE SOLENOID MANIFOLD REPAIR (CONT).
(13)
Remove five plugs (50) and preformed
packings (51) from solenoid housing (1).
Discard preformed packings.
(14)
Remove two plugs (52) and preformed
packings (53) from solenoid housing (1).
Discard preformed packings.
(15)
Remove plug (54) and preformed
packing (55) from solenoid housing (1).
Discard preformed packing.
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts in drycleaning solvent.
(2)
Dry parts with cleaning cloth.
(3)
Inspect each part for cracks, gouges, pitting and stripped threads.
(4)
Replace damaged parts.
|