TM 9-2320-364-34-3
17-32
17-4. MAIN HYDRAULIC PUMP CONTROL SUBASSEMBLY REPAIR (CONT).
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
d.
Assembly.
NOTE
Assembly of front control
subassembly and rear control
subassembly are identical. Front
control subassembly is shown for
assembly.
Install adjusting screw (3) and jam nut (2)
front control subassembly (1).
e.
Installation.
NOTE
If installing rear control
subassembly, perform
Steps (1) and (2).
If installing front control
subassembly, perform
Steps (3) and (4).
Install elbow and adapter as
noted prior to removal.
(1)
Apply hydraulic oil to preformed
packing (16).
(2)
Install preformed packing (16) and
adapter (9) in rear control subassembly (6).
Tighten nut (15) in adapter (9).
OUTSIDE PUMP
CONTROL SETSCREW
(DO NOT ADJUST)
1
3
2
|