TM 9-2320-364-34-3
18-206
18-13. CONTAINER HANDLING UNIT (CHU) KIT INSTALLATION (CONT).
NOTE
Stow hooks are not tightened
on stow weldment.
Stow hook should have an
even gap around LF pin.
(18)
Tighten eight screws (346) and locknuts
(347) on two hooks (348) and stow
weldment (59).
(19)
Verify LF wear pad gap to LHS hook arm
is less than 1/8 in. (3.2 mm). If not repeat
Steps (13) through (18).
(20)
Operate right rotary paddle (340) and left rotary paddle (342) (TM 9-2320-364-10).
(21)
If right rotary paddle (340) or left rotary paddle (342) bind, adjust rotary paddles (TM 9-2320-364-20).
348
346
347
59
340
342
|