TM 9-2320-364-34-3 18-208 18-13.  CONTAINER HANDLING UNIT (CHU) KIT INSTALLATION (CONT). NOTE Moving proximity switch towards rear lengthens hook arm cylinder. Moving proximity switch towards front shortens hook arm cylinder. (28) Loosen two nuts (303) on proximity switch (302) and move proximity switch as required. (29) Tighten two nut (303) on proximity switch (302). (30) Start engine and stow LHS (TM 9-2320-364-10). (31) Repeat Steps (25) through (28) until hook arm cylinder length is 77 in. 0.25 in. (196 cm 0.64 mm). (32) Using feeler gage, adjust clearance between CHU proximity switch (302) and sensor plate (295) to 0.125 in.  0.01 in. (3.18 mm  0.25 mm) and tighten nuts (303). (33) Start engine and stow LHS (TM 9-2320-364-10). (34) Shut OFF engine. 295 301 0.125 IN.  0.01 IN. (3.18 MM  0.25 MM) 77 303 303