TM 9-2320-364-34-3
18-271
NOTE
Disconnect connector by prying
up on tabs and gently pulling
apart connector.
(21)
Disconnect MC106 connector (23).
(22)
Unlatch and open two secondary locks (24)
on MC106 connector (23).
Tip of removal tool is very sharp.
Use caution when using tool.
Failure to comply may result in
injury to personnel.
(23)
Insert removal tool into position B (25) on
MC106 connector (23) until seated.
(24)
Pull wire 505 (26) back through MC106
connector (23) and remove tool.
(25)
Cut terminal (27) and wire seal (28) from
end of wire 505 (26). Discard terminal and
seal.
(26)
Install heat shrink (29) over end of wire
505 (26) and seal using heat gun.
(27)
Remove plug (30) from position D (31) on
MC106 connector (23).
|