TM 9-2320-364-34-3      18-273 (35) Install plug (36) in position B (34) on MC106 connector (23). (36) Mark wire 505 (35) as wire 953. (37) Install wire 953 (35) in position D (37) on MC106 connector (23) until seated. (38) Close secondary locks (33) on MC106 connector (23). (39) Connect MC106 connector (23). (40) Disconnect MC102 connector (38) from DDEC 6.8k resistor (39). (41) Unlatch and open two secondary locks (40) on MC102 connector (38). Tip of removal tool is very sharp. Use caution when using tool. Failure to comply may result in injury to personnel. (42) Insert removal tool into position B (41) on MC102 connector (38) until fully seated. (43) Remove wire 1435 (42) back through MC102 connector (38) and remove tool. (44) Cut terminal (43) and wire seal (44) from end of wire 1435 (42).  Discard terminal and seal.