TM 9-2320-364-34-4
20-322
20-100. RIGHT THERMOSTAT HOUSING INSTALLATION (CONT).
b.
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(1)
Coat threads of screw (10) with sealing
compound.
(2)
Position screw (10) in cylinder head (15)
three turns deep.
(3)
Coat gasket (14) with grease.
(4)
Position gasket (14) on right thermostat
housing (8).
(5)
Install gasket (14) and right thermostat
housing (8) with two lockwashers (13) and
screws (11) and (12).
(6)
Tighten screws (10) and (11) to 23 to 26
lb-ft (31 to 35 N.m).
(7)
Tighten screw (12) to 35 to 38 lb-ft (47 to
52 N.m).
NOTE
Long screw, lockwasher, and clip
will be installed in turbocharger and
air inlet housing installation task.
(8)
Coat gasket (7) with grease.
(9)
Position gasket (7) on thermostat housing
cover (6).
(10)
Position two hose clamps (1) on hose (2)
and on thermostat housing cover (6).
(11)
Install thermostat housing cover (6) and
clip (5) on right thermostat housing (8)
with four lockwashers (4) and screws (3).
Tighten 23 to 26 lb-ft (31 to 35 N.m).
(12)
Position hose (2) and position hose
clamps (1) on water pump (9).
(13)
Tighten two hose clamps (1).
c.
Follow-On Maintenance:
Install left thermostat housing, (Para 20-101).
END OF TASK
|