TM 9-2320-364-34-4
20-324
20-101. LEFT THERMOSTAT HOUSING INSTALLATION (CONT).
b.
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(1)
Coat threads of connector (13) with sealing compound.
(2)
Install connector (13) in left thermostat
housing (9).
(3)
Position hose (11) and two clamps (10) on
left thermostat housing (9).
(4)
Coat gasket (18) with grease.
(5)
Position gasket (18) and left thermostat
housing (9) on engine (19). Line up with
hose (11).
(6)
Position hose (11) on tube elbow (12).
(7)
Coat threads of screws (14) and (15) with
sealing compound.
(8)
Install two screws (14) and (15) through left
thermostat housing (9) into cylinder
head (18). Tighten screws 23 to 26 lb-ft (31
to 35 N.m).
(9)
Install lockwasher (17) and screw (16).
Tighten screw 23 to 26 lb-ft (31 to 35 N.m).
(10)
Tighten two clamps (10) on hose (11).
(11)
Coat gasket (8) with grease.
(12)
Position gasket (8) on thermostat cover (4).
NOTE
Screw for right front holes will
be installed with ECM bracket.
(13)
Install thermostat cover (4) and clip (7) with
three lockwashers (6) and screws (5).
Tighten screws 23 to 26 lb-ft (31 to 35 N.m).
(14)
Install crossover tube (3), two hoses (2) and
four clamps (1) on thermostat covers (4).
c.
Follow-On Maintenance:
Install engine lifting brackets, (Para 20-102).
END OF TASK
|