DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
WARNING
Wear protective goggles and nonleather gloves when servicing air conditioner system. Failure to
comply may result in injury to personnel.
VISUAL INSPECTION
Inspect AC condenser core for damage and blockage
from debris.
5. Verify repair, go to Step 29 of this fault.
(b) If AC condenser core is blocked with debris,
remove blockage. Verify repair, go to Step 29 of
this fault.
(c) If AC condenser core is free from damage and
blockage, go to Step 2 of this fault.
PLSAC171