AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM DUCTS DURING AC OPERATIONS - Continued
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM DUCTS DURING AC OPERATIONS - Continued

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  62    63    64    65    66  67  68    69    70    71    72  
img
. . . . .
DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
WARNING
Wear protective goggles and nonleather gloves when servicing air conditioner system. Failure to
comply may result in injury to personnel.
VISUAL INSPECTION
Inspect AC condenser core for damage and blockage
from debris.
(a) If AC condenser core is damaged:
1. Recover R-134a refrigerant (WP 0053).
2. Replace AC condenser core (WP 0023).
3. Replace AC condenser dryer (WP 0024).
4. Evacuate and charge system (WP 0053).
5. Verify repair, go to Step 29 of this fault.
(b) If AC condenser core is blocked with debris,
remove blockage. Verify repair, go to Step 29 of
this fault.
(c) If AC condenser core is free from damage and
blockage, go to Step 2 of this fault.
PLSAC171
0012-3