DRAFT
TB 9-2320-364-13&P-1
AC DOES NOT COOL OR COOLS INADEQUATELY - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
14.
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to AC system OK.
Visual inspection.
REASON FOR QUESTION
AC control circuit OK (except for temperature
Is AC hose from low-side AC
control and low pressure switches).
If frost or cool spots are
Low pressure switch OK.
service valve to AC
forming on AC hose, AC
No AC condenser dryer desiccant
hose is restricting R-134a
contaminant in AC refrigerant system.
refrigerant flow.
and cool spots?
No AC refrigerant oil contaminant in AC
refrigerant system.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC system charge is not low.
No AC system leaks.
Temperature control switch OK.
Recover R-134a
No air or other contaminant in AC refrigerant
refrigerant
system.
NO
AC condenser dryer OK.
restricted AC hose
AC evaporator core OK.
No moisture in AC refrigerant system.
condenser dryer
YES
Evacuate and charge
AC system not overcharged.
Verify repair, go to
POSSIBLE PROBLEMS
Step 22 of this fault.
Restricted AC hose.
AC compressor faulty.
AC expansion valve faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
15.
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to AC system OK.
Pressure test.
AC test set manifold gage.
AC control circuit OK (except for temperature
REASON FOR QUESTION
Does system high-side
control and low pressure switches).
Low pressure switch OK.
pressure vary with engine
If system high pressure
No AC condenser dryer desiccant
RPM?
varies with engine RPM,
contaminant in AC refrigerant system.
AC expansion valve is
faulty. If not, AC
No AC refrigerant oil contaminant in AC
refrigerant system.
AC system charge is not low.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
No AC system leaks.
Recover R-134a refrigerant
Temperature control switch OK.
No air or other contaminant in AC refrigerant
system.
NO
AC condenser dryer OK.
Evacuate and charge system with
AC evaporator core OK.
new R-134a refrigerant
No moisture in AC refrigerant system.
YES
Step 22 of this fault.
AC system not overcharged.
No restricted AC hoses.
POSSIBLE PROBLEMS
AC compressor faulty.
Evacuate and charge system with new
AC expansion valve faulty.
repair, go to Step 22 of this fault.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0015-22