45. Drill 0.469 in. (11.91 mm) hole (68) on
side of ECB (69).
46. Install 20 amp circuit
breaker (70) on ECB (69)
with nut (71). Tighten
nut (71) to 16-24 lb-in
(1.8-2.7 Nm).
47. Connect wire assembly
1082 (72) to terminal on
20 amp circuit breaker (70).
48. Install wire (73) on 20 amp
circuit breaker (70) with
screw (74) and lockwasher (75).
49. Install wire (73) on circuit
breaker 15 (76) with
screw (77) and lockwasher (78).
0055-45