TM 5-3990-263-13&P
0032
CORRECTIVE ACTION - Continued
MALFUNCTION
Wiring Between Connectors J4 and P2 is Faulty (Model B Only).
CORRECTIVE ACTION
CAUTION
Electrical power must be shut OFF from circuit before continuity can be checked.
Failure to comply with this caution may result in damage to test equipment or
electrical system.
NOTE
Digital controller and cab control box are not repairable, therefore, it is necessary
to test digital controller and cab interface wiring harnesses, switches, solenoids,
and other components to identify possible faults other than digital controller and
digital cab controller.
1.
Remove 6 screws and flat washers from hydraulic cabinet cover and remove cover (Figure 14).
HYDRAULIC CABINET
COVER
WINCH OUT
SOLENOID
FLATWASHER
CONNECTOR
J3
SCREW
POSITION
33
POSITION 1
J4
POSITION 2
POSITION
POSITION
35
1
Figure 14. Hydraulic Cabinet Cover, WINCH OUT Solenoid Connector, and Connector J4.
2.
Disconnect right hand connector J3 (40 pin connector) from digital controller (Figure 14).
3.
Disconnect left hand connector J4 (40 pin connector) from digital controller (Figure 14).
4.
Set multimeter to ohms position.
NOTE
A reading of infinity indicates an open circuit.
5.
Place negative (-) probe of multimeter on position 1 of digital controller wiring harness connector
J4 (Figure 14).
6.
Place positive (+) probe of multimeter on position 2 of digital controller wiring harness connector
03/15/2011Rel(1.8)root(tswp)wpno(T03028)