TM 5-3990-263-13&P
0036
Table 1.
FIELD LEVEL PMCS - Continued
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
Check winch frame locking levers (Figure 3, Item 3) for Winch frame locking
cracks, broken weldments, or damage and for freedom levers are cracked, have
of movement.
broken weldments, are
damaged, or have no
freedom of movement.
4
Semi-
BAP Winch
Check fluid level from winch filler port (Figure 4, Item 1). Any Class III leaks are
Annual
Assembly and
found.
Cable Tensioner
2
1
Figure 4. Winch Assembly.
Check mounting screws (Figure 4, Item 2). Replace
Mounting screws are
mounting screws (Figure 4, Item 2) if broken or missing broken or missing.
5
Semi-
BAP Winch
Inspect input ports to winch hydraulic motor (Figure 5,
Annual
Hydraulic
Item 1) for leaks.
System
2
1
3
Figure 5.
Winch Hydraulic System.