MANUALLY LOADING BRIDGE ADAPTER PALLET (BAP) FROM THE GROUND
Figure 3. Cab LHS Controls

Parts Manual For Pallet, Adapter, Bridge M15 Page Navigation
  148    149    150    151    152  153  154    155    156    157    158  
img
.
TM 5-3990-263-13&P
0017
PERFORM PROCEDURE - Continued
4.
Ensure BAP hold-down locks (Figure 2, Item 3) are in auto engage position (handle pushed in).
3
SHOWN WITHOUT BAP INSTALLED
FOR CLARITY
Figure 2.
Check Hold-Down Locks.
5.
Back up vehicle so that at least 5 ft. (1.5 m) of clearance is available behind vehicle for loading the BAP. Refer
to TM 9-2320-425-10 or TM 9-2320-435-10.
NOTE
Dashboard parking brake indicator will illuminate when PARKING BRAKE control is applied.
6.
Pull out PARKING BRAKE control (Figure 3, Item 4) or apply service brake pedal (Figure 3, Item 5).
0017-2