TM 5-3990-263-13&P
0035
Table 1.
Operator Preventive Maintenance Checks and Services - Continued
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
in sections of cable; that is,
if six wires are broken in
one 3 in (7.62 cm) section
of cable, none would be
allowed in next 3 in (7.62
cm) section.
STRAND
WIRE
INDICATES
BROKEN
CABLE
WIRE
3 in.
3 in.
3 in.
3 in.
SERVICEABLE
SERVICEABLE
UNSERVICEABLE
SERVICEABLE
1
UNSERVICEABLE
UNSERVICEABLE
UNSERVICEABLE
Figure 11. Winch Cable.
WARNING
15
During
Remote Control
Unit
Check for overhead power lines or other ob-
structions before attempting operation of
LHS. LHS reaches a height of 22 ft 2 in. (6.7
m) and could contact power lines. Failure to
comply may result in serious injury or death
to personnel.
CAUTION
BAP must be unloaded and winch frame un-
locked from BAP before checking remote
control unit. Failure to comply may result in
damage to equipment.
Remove remote control unit (Figure 12, Item 1) from
stowage box (Figure 12, Item 2) and check for damage.
03/15/2011Rel(1.8)root(pmcswp)wpno(I04003)