TM 5-3990-263-13&P
0062
5
6
1
2
4
3
Figure 3.
2.
Push hand pump selector (Figure 3, Item 3) to down position.
3.
Fill hand pump (Figure 3, Item 2) with fluid until dipstick (Figure 3, Item 1) hole shows fluid level. Slowly pump
handle (Figure 3, Item 4) so fluid level spreads to hydraulic system until no air comes out of plug or test fitting
at manifold (Figure 3, Item 5).
4.
Fill hand pump (Figure 3, Item 2) with hydraulic fluid until fluid level reaches dipstick (Figure 3, Item 1) hole.
5.
Push hand pump selector (Figure 3, Item 3) to up position.
6.
Slowly pump handle (Figure 3, Item 4) as fluid level spreads to hydraulic system until no air comes out of plug
or test fitting at center roller manifold (Figure 3, Item 6). Fill hand pump (Figure 3, Item 2) with fluid until dipstick
(Figure 3, Item 1) hole shows fluid level.
7.
Continue filling hand pump (Figure 3, Item 2) with hydraulic fluid until fluid level reaches dipstick (Figure 3,
Item 1) hole.
8.
Install dipstick (Figure 3, Item 1) in hand pump (Figure 3, Item 2).
9.
Move hand pump selector (Figure 3, Item 3) to center position.
END OF TASK
END OF WORK PACKAGE